Wind Speed Sensor - Company Ranking(6 companyies in total)
Last Updated: Aggregation Period:Jul 16, 2025〜Aug 12, 2025
This ranking is based on the number of page views on our site.
Display Company Information
Company Name | Featured Products | ||
---|---|---|---|
Product Image, Product Name, Price Range | overview | Application/Performance example | |
This product is a separate type of wind direction and wind speed meter. The wind direction meter and wind speed meter do not interfere with each other, making it easier to respond to slight changes in wind compared to airplane models. It is compact and lightweight, with higher durability than previous models from the manufacturer, and improved accuracy in wind direction. It can be easily installed on poles, etc., using the included mounting band. | Anemometer | ||
The heater element heated to a certain temperature calculates the flow rate by measuring the change in heat quantity influenced by wind speed. The M261A10 probe uses a thin film sensor element. The thin film sensor consists of a nickel resistance thermometer and a nickel resistance heater. The time constant (t95) of the M261A10 thin film sensor element is approximately 1 second at a standard air velocity of about 5 m/s. The thermal type wind speed sensor can measure not only in low wind speed ranges but also in high wind speed ranges and high-temperature environments. ■ Measurement Examples Air measurement for compressors, measurement of natural gas consumption - Flow rate and laminar flow measurement in pharmaceutical manufacturing and semiconductor production processes - Flow rate measurement for various compressor air, air knives, etc. ■ Measured Gases Normal air, gases, mixed gases: Atmospheric air, nitrogen, methane, natural gas, argon, helium, biogas, carbon dioxide, and others. | Wind speed measurement range: 0 to 200 m/s (according to sensor specifications) Accuracy (0.2 to 40 m/s): ±2% mv. + 0.02 m/s (above 40 m/s): ±2.5% m.v. (m.v.: indicated value) Operating temperature range: -10 to +140°C Maximum measurable pressure: 16,000 hPa Standard sensor dimensions: φ10×285 mm Cable length: 3 m EMC compliance: IEC1000-4, EN50081, EN6100 Protection rating: IP68 Connector: IP65 | ||
This is an introduction to the "Ultra Low Wind Speed Sensor" handled by Shiro Sangyo, a specialized online shopping site for measuring instruments, packaging equipment, and logistics equipment, which selects and provides better products and services from around the world. 【Features】 ○ Capable of measuring in two opposing directions, allowing for the capture of indoor airflow direction ○ Can accurately measure low wind speeds without being affected by room temperature or wind temperature ○ Method: Thermal (Thermistor) ○ Response speed: Time constant within 1 second ● For other functions and details, please download the catalog. | For more details, please contact us. | ||
---
--- |
--- |
-
- Featured Products
-
Wind direction and wind speed sensor, separate type / M694TF-56W-L10
- overview
- This product is a separate type of wind direction and wind speed meter. The wind direction meter and wind speed meter do not interfere with each other, making it easier to respond to slight changes in wind compared to airplane models. It is compact and lightweight, with higher durability than previous models from the manufacturer, and improved accuracy in wind direction. It can be easily installed on poles, etc., using the included mounting band.
- Application/Performance example
- Anemometer
Thermal type wind speed sensor / Model number M261A10-285GE-30m
- overview
- The heater element heated to a certain temperature calculates the flow rate by measuring the change in heat quantity influenced by wind speed. The M261A10 probe uses a thin film sensor element. The thin film sensor consists of a nickel resistance thermometer and a nickel resistance heater. The time constant (t95) of the M261A10 thin film sensor element is approximately 1 second at a standard air velocity of about 5 m/s. The thermal type wind speed sensor can measure not only in low wind speed ranges but also in high wind speed ranges and high-temperature environments. ■ Measurement Examples Air measurement for compressors, measurement of natural gas consumption - Flow rate and laminar flow measurement in pharmaceutical manufacturing and semiconductor production processes - Flow rate measurement for various compressor air, air knives, etc. ■ Measured Gases Normal air, gases, mixed gases: Atmospheric air, nitrogen, methane, natural gas, argon, helium, biogas, carbon dioxide, and others.
- Application/Performance example
- Wind speed measurement range: 0 to 200 m/s (according to sensor specifications) Accuracy (0.2 to 40 m/s): ±2% mv. + 0.02 m/s (above 40 m/s): ±2.5% m.v. (m.v.: indicated value) Operating temperature range: -10 to +140°C Maximum measurable pressure: 16,000 hPa Standard sensor dimensions: φ10×285 mm Cable length: 3 m EMC compliance: IEC1000-4, EN50081, EN6100 Protection rating: IP68 Connector: IP65
Ultra-low wind speed sensor M1069S-03BE
- overview
- This is an introduction to the "Ultra Low Wind Speed Sensor" handled by Shiro Sangyo, a specialized online shopping site for measuring instruments, packaging equipment, and logistics equipment, which selects and provides better products and services from around the world. 【Features】 ○ Capable of measuring in two opposing directions, allowing for the capture of indoor airflow direction ○ Can accurately measure low wind speeds without being affected by room temperature or wind temperature ○ Method: Thermal (Thermistor) ○ Response speed: Time constant within 1 second ● For other functions and details, please download the catalog.
- Application/Performance example
- For more details, please contact us.
-
Membership (free) is required to view all content.
Already a Member? Log In Here